The main performance characteristics:
    In line with national GB / T13582-92, GB / T14218-93, GB / T15734-1995 quality testing standards, reliable quality.
    With a DMX-512 interface, RGB network interface and RJ-45 standard LAN Ethernet interface to support the network connection of the silicon cabinet, and support ACN network protocol.
    The use of optical isolation of the input interface to avoid high-voltage anti-string back to the control side and affect the work of the console.
    Dual system, dual decoding, dual-trigger, duplex dual backup work, the main and vice-system backup each other, intelligent switching, to ensure high reliability and high stability silicon cabinet.
    DMX signal has A / B two independent inputs, can be set to separate (A or B) / mixed (the first priority) / backup (A priority, automatic switching) mode of operation.
    Scene backup function: DMX signal field can be recorded, since the programming field, modify, delete, run the field.
    On-site dimming function: 96/60-channel digital dimming can be arbitrarily set the brightness of any silicon road; with total control, easy to start / close the scene dimming function.
    (DMX signal value) can be observed in a variety of ways; can look at the output circuit of the "three-phase input voltage", the output voltage and current can be a variety of ways to see the dimming brightness (DMX signal value) OK "/ open / shorted.
    System Status Telemetry and Reporting (Reporting): The system status of cabinet temperature, silicon temperature, three phase input voltage, silicon output voltage and current, cooling fan speed and so on can be sent back to the control room through LAN network or RGB telemetry. Telemetry and reporting of system status.
    Cooling fan automatic switching function: When the silicon cabinet output and the temperature exceeds 48 ℃ when the fan is turned on, or shut down the fan.
    Over-temperature alarm and protection: Alarm and protection can be realized on both the silicon cabinet and the reporting system of the control room at the same time: when the silicon block temperature exceeds 80 ℃ or the temperature of the silicon counter exceeds 60 ℃ (this critical temperature value can be changed) ; When the silicon block temperature exceeds 105 ℃ or silicon counter temperature exceeds 80 ℃ can start the automatic protection function (can also prohibit the automatic protection function); with output over-current (short circuit) protection, to avoid burning silicon.
    High trigger accuracy: 1024 level.
    Dimming curve selection function: preset 12 user-selectable dimming curve, and
    Can be set according to user needs any special dimming curve, excellent linearity and consistency of light.
    Imported high-quality SCR, a new design package module, can resist short-circuit instantaneous.
    The use of high-performance anti-interference magnetic ring, excellent anti-interference ability.
    There are 96 circuits (each road 6KW), 60 loops (each road 6KW).